    Product Specifications
    • 24 VDC +/- 10%
    • Less than 1.2 watt at 24 VDC Volt-Ampere (VA)
    • Temperature: +/- 0.5% of FS ; Humidity: +/- 1.8 Percent of FS ; Differential Pressure: +/- 0.5 % of FS mm/m
    • Digital Only
    • As mentioned in Product Description
    Product Description

    Features:

    • LED display Indication for Temperature , Humidity and Differential Pressure at a time.
    • Remote Temperature and RH sensor Connection facility
    • Independent Programmable alarm for Temperature, Humidity and Differential Pressure.
    • In built Buzzer for Alarm set points with acknowledgment facility
    • Software calibration facility.
    • Password protected programming.
    • Isolated RS-485 communication with Modbus RTU Protocol.


    Applications:

    • Clean room application in Pharmaceutical
    • Pharma Environments monitoring applications.
    • HVAC (Heating, ventilation, Air conditioning, Cooling).
    • Animal house clean room


    Technical Specification:

    Input

    Sensors

    Remote Humidity and Temperature Sensor, Built in differential pressure sensor with Brass Hose Nipples (Chrome Plated) for +ve Pressure connection& -ve Pressure connection provided on SS front plate

    Indication

    Differential Pressure

    Upper 4 digit Seven segments 0.4 inch RED LED display

    Temperature

    Middle 4 digit Seven segments 0.4 inch RED LED display

    Humidity

    Lower 4 digit Seven segments 0.4 inch RED LED display

    Status indication

    3 LEDs for alarms Integrated Buzzer for process violation of alarm limits any of the 3 parameters.

    Accuracy

    Temperature

    +/- 0.5% of FS

    Humidity

    +/- 1.8 Percent of FS

    Differential Pressure

    +/- 0.5 % of FS

    Range

    Temperature

    -30.0 Degree Centigrade to 50.0 Degree Centigrade

    Humidity

    0 Percent to 100 Percent RH

    Differential Pressure

    -500 to 500 pascal

    Display resolution

    0.1 for Temperature and RH, 1 for Differential Pressure

    Communication

    Communication

    Isolated RS-485 communication with Modbus RTU Protocol

    Programmable parameter

    Baud rate, Parity, Data bits, Stop bits

    No. of salve ID

    1-250

    Programmable Parameters

    Set point

    Programmable as per input selection

    Programming of parameters

    3 Nos. push button front keys (with password protection) Alarm logic: High or Low programmable

    Environmental

    Operating Ambient Temp.

    0 to 50 Degree Centigrade

    Humidity

    Below 90 Percent RH, Non condensing.

    Dimension:

    Flush mounting plate

    SS-304

    Front plate size

    110 mm(W) x90 mm(H)

    Back enclosure

    76 mm (W) x 70 mm(H) x 45 mm(D) MS with powder coated

    Mounting

    Modular wall mounting with Stainless Steel Front

    Electrical

    Supply voltage

    24VDC +/- 10 Percent

    Power consumption

    Less than 1.2 watt at 24VDC


    Trade Information
    • Mumbai
    • Telegraphic Transfer (T/T), Cheque, Cash in Advance (CID)
    • 3-4 Week
    • Africa, Middle East, Australia, Asia
    • All India
    Contact Us

    17-B, Tarun Industrial Estate, Mogra Pada, New Nagardas Road, Andheri (East) Mumbai Maharashtra India +918068090472
    Phone :+918068090472