We have a long list of clients who choose our company for manufacturing and exporting a wide stock of Ethernet Modem. All these modems are installed in the a network for wireless communication of data. Manufactured by implementing latest technology, the offered modem is superior in performance. Available in different specifications and models, these modems are compatible with different process control instruments. Our clients can get this Ethernet Modem from us at competitive prices.
Features
Alarm and Fault Notifications
Fault Notification | Automatic generation and dispatch of more than 100 fault notifications Condition based monitoring of data may launch events Message templates may include current values from PLC or Tixi Data Gateway Up to 100 predefined events may trigger actions. |
Alarm Cascade | Message confirmation may be implemented by means of freely definable alarm levels. |
Address Book | Address book with more than 100 contacts |
Message Templates | More than 100 message templates may contain variable values from PLCs or the Tixi Data Gateway. Destination addresses and PLC variables are defined as references. Message length is not restricted (only by memory size). |
Neutral Data | |
Data Converter | All data of local systems connected to the device (PLCs, meters, sensors etc) are managed by means of a neutral variable table (XML). These XML-data are independent of their origin. All Tixi functions use these neutral data. Local PLC data may thus be translated from one system to another, e.g. meter data may be handed to a PLC or BMS (building management system). |
Data Logger | |
Data Logging | All values (e.g. PLC or meter values) may be logged on a regular basis. |
Data Dispatch | Saved Log data may be sent as E-Mail attachments at scheduled times or as a result of any event. Their format is to be freely defined, such as XML or Microsoft Excel CSV. |
Embedded Webserver | |
Webserver | The user may create custom websites with any HTML editor, including XML placeholders for system values. By means of these websites, current data may be displayed or custom input masks can be defined. Common Gateway Interface (CGI) for dynamic read and write of values and for log data readout. Special SSI (Server side Includes) allow embedding of values and log data into websites. |
Remote Control | |
Switching Commands | Switching commands may be transmitted via E-Mail, HTTP or TiXML command onto the Tixi Data Gateway. HTTP and TiXML commands may be defined freely and may contain e.g. setpoint values. |
Confirmation | If need be, the device may send confirmation commands upon receipt and execution of a remote switching command, in order to report the positive (or negative) result of such. |
Programmable Features | |
Scheduler | Event Calendar may trigger the following actions: - Creation of logfile entries or dispatch of logfiles, - Switching I/Os or setting PLC variables, - Dispatch of periodic status messages - Automatic shift schedules may change the receiver of messages. |
Logical Operations | Functions (e.g. AND, OR, XOR, NOT) and Comparisons (z.B. GT, LT, EQ) can be applied to variable values, even along with time schedules, may trigger actions. |
Sequencer | Time-dependent data arrays can be preset over a specific span of time, either via configuration or by message. E.g monitoring of current values and dispatch of messages in case that current values exceed min./max. curves (depending on a time grid of 15-min-steps up to one year). Several curve sets may be used in conjunction or as separate data sets. |
Arithmetic Operations | Simple arithmetics (ADD, SUB, MUL, DIV) allows calculation with PLC and variable values. |
Configuration | |
TiXML | TiXML is the XML based command language used to configure Tixi devices. Via TiXML, programs and devices may easily communicate with Tixi devices. |
Configuration | TiXML via TCP/IP or COM1 RS232 or via batch file on an SD card. |
Security | Access to the Tixi device and to the configuration is protected by several levels of login and password - both remotely and locally. |