AMBETRONICS ENGINEERS PVT. LTD.
Infrared Dual Gas Sensor Transmitter

Infrared Dual Gas Sensor Transmitter

Send Inquiry

We have a well equipped production unit, loaded with advanced technology machines and tools, enabling us to manufacture and supply a quality range of Bio Gas Detection. Our detectors provide effective solution to the biogas, oil wells and gas turbines by detecting any leakage of combustible gases. To manufacture the detectors, we use high quality materials and components, sourced from trusted vendors. We offer our Bio Gas Detection at the market leading prices. 

Features:

  • Accurate detection
  • Easy handling
  • Highly efficient 

Further Details:

The Aero sense IR-5500 provides an effective solution for protection against hazardous gases by detecting wide range of combustible gases and CO2 simultaneously.

FEATURES:   

  • Higher accuracy and better lifetime achieved using NDIR sensor Technology.
  • Optimized for detection of smallest leak of combustible gases and Carbon Dioxide.
  • Highly resistant to poisoning and etching.
  • Capable of detecting down to PPM, %LEL, %V/V, mg/m3.
  • Auto ranging of Gas Concentration from PPM to %V/V & %LEL.
  • Digital Alphanumeric display with Auto backlit.
  • Standard 4-20mA signal output proportional to Gas concentration range.
  • Easy handling and programming with 3 keys.
  • Can be programmed using Remote Control from 10 meters line of site distance.
  • Non - Intrusive programming for Flameproof models using Magnetic pen.
  • Password protected programming menu.
  • One man Auto software Gas calibration.
  • Optional alarm relay contacts with two configurable alarm levels.
  • Optional RS-485 communication port with MODBUS RTU Protocol. 

APPLICATIONS:  

  • Biogas.
  • Oil Wells.
  • Breweries.
  • Steel Plants.
  • Gas Turbines.
  • Chemical Industries.

TECHNICAL SPECIFICATION

Detection Method

NDIR, IR Absorption, Dual Wavelength Multipath

IR Source

Tungsten Filament light bulb, pulsated at 4 Hz

Gas Detected

Hydrocarbons and Carbon Dioxide

Accuracy

 +1% of the full scale value

Signal output

Industrial standard 4-20mA DC O/P with permissible load 750 ohm at 24 VDC, 25mA

Display

8 X 2 Alpha Numeric LCD Display

Set point

Two independent set point, LO & HI with blinking indication with programmable latch & non-latch Facility only for indication purpose. 

Setting

Setting by 4 keys on front panel i.e. 'SET / NEXT', 'UP', 'DOWN' & 'TEST / BACK'

Monitoring

I) By Display :Sensor Break/ Open / Over range / Under range Shows "Err" Indication
ii) By loop current : Upscale current : 22mA, Down scale current : 3.6mA to 3.9mA, Selectable

Supply Voltage

14VDC to 36VDC

Cable

1.5 sq. mm 3 Core, Flexible OR Armored shielded cable

Operating Temperature

0 to 50oC, +5%, Relative humidity: Below 95% non condensing

Sensor Housing

P.V.C. / P.P. / SS304 / SS316, Please specify while ordering

Enclosure Detail

GT-5500-WP (Weatherproof )

GT-5500-FLP (Flameproof )

Protection Class

IP-65

IP-65 for Gas Gr. IIA & IIB, CCOE & CMRI Approved

Cabinet Material

Polycarbonate, gray colour

Cast Aluminium alloy, LM-6 / C.I. Enclosure

Cable Entry

1 No, Thermoplastic cable gland (IP 68)

1 No. Double compression cable gland (Ex-Proof), 3/4" ET type

Dimension

155mm(H) x 100mm(W) x 55mm(D)

175mm(H) x 205mm(W) x 120mm(D)

Mounting

Wall Mounting / Stand Mounting

Wall Mounting / Stand Mounting

Weight

500 Grams

2 Kg