Loop Power Indicator Panel Mount

Loop Power Indicator Panel Mount
Loop Power Indicator Panel Mount
Product Code : LPI-350 PM
Price And Quantity
Minimum Order Quantity :
1
Unit of Measure :
Piece/Pieces
Product Specifications
Accuracy :
+/- 1 percent Of Full Scale Value. %
Material :
ABS PLASTIC, White Color
Voltage :
4 - 20 mA Loop Current Input from any 2 / 3 Wire Process Transmitter Milliampere (mA)
Size :
96 (H) X 96 (W) X 75 (D) in mm
Weight :
Approx. 250 Grams (g)
Product Description

FEATURES:-

  • Minimum loop voltage drop
  • Option of range locking and unlocking
  • High level of accuracy
  • User Programmable with Password Protection.
  • Easy Programming with Push Buttons.
  • Software Calibration - No Trim pots.
  • Reverse Polarity Protection.
  • Loop Voltage Drop < 5 VDC.
  • 4-20 mA Loop Current Input from Transmitters.
  • Accuracy +/- 1 percent Of Full Scale Value.
  • 0.5 inch, 3 1/2 Digit L.C.D Display.
  • Range Locking / Unlocking Facility.
  • Offset Facility To Compensate Field Error.
  • Operational Mode Linear / Square Root; Programmable by user.


APPLICATIONS:-

  • Provides Process value Indicator in various Industrial Control & Measurement Application such as Pressure, Flow, Level, Temp.,Humidity etc.
  • Remote Indicator at point of measurement or at control end especially where there is no power source.
  • Being Non Voltage Producing Device can be directly used in Hazardous Area with Suitable Enclosure.
  • Replaces an Analog Meter with no additional wiring and power connection.
  • Can be inserted at any point in signal loop as a standaloneas it requires no external power.
  • Remote Indication location on tank taps as used in liquid level sensing & control.

 

Technical Specifications:-

Input:

4 - 20 mA Loop Current Input from any 2 / 3 WireProcess Transmitter

Range

-1999 To 1999 with Range Lock / Unlock; programmableby user

Resolution

0.001, 0.01, 0.1, 1; programmable by user

Accuracy

Linear - +/-0.1 percent of span; Square root - +/-0.2percent of span

Operational Mode

Linear & Square root; programmable byuser

Loop Voltage Drop

< 5 VDC

Display

0.5 inch, 3 1/2 digit L.C.D Display

Display Update Rate

Linear mode - 0.8 sec; Square root mode- 0.8 sec

Monitor:

Display shows Und, when I/P current fallsbelow 3.6 mA

Display shows our, when I/P current goes above 20.5 mA

Operating Temperature

- 40 To 85 Deg.C

Relative Humidity

Below 95percent non condensing

Warm up Time

10 Sec

Enclosure Detail

PANEL MOUNTING ENCLOSURE

Protection Class

IP - 40

Cabinet Material

ABS PLASTIC, White Colour

Cable Entry

Terminal Connector For Connection

Dimension

96 (H) X 96 (W) X 75 (D) in mm

Cutout

92 (H) X 92 (W) in mm

Mounting

Panel Mounting

Weight

Approx. 250 Grams


FEATURES:-

  • Minimum loop voltage drop
  • Option of range locking and unlocking
  • High level of accuracy
  • User Programmable with Password Protection.
  • Easy Programming with Push Buttons.
  • Software Calibration - No Trim pots.
  • Reverse Polarity Protection.
  • Loop Voltage Drop < 5 VDC.
  • 4-20 mA Loop Current Input from Transmitters.
  • Accuracy +/- 1 percent Of Full Scale Value.
  • 0.5 inch, 3 1/2 Digit L.C.D Display.
  • Range Locking / Unlocking Facility.
  • Offset Facility To Compensate Field Error.
  • Operational Mode Linear / Square Root; Programmable by user.


APPLICATIONS:-

  • Provides Process value Indicator in various Industrial Control & Measurement Application such as Pressure, Flow, Level, Temp.,Humidity etc.
  • Remote Indicator at point of measurement or at control end especially where there is no power source.
  • Being Non Voltage Producing Device can be directly used in Hazardous Area with Suitable Enclosure.
  • Replaces an Analog Meter with no additional wiring and power connection.
  • Can be inserted at any point in signal loop as a standaloneas it requires no external power.
  • Remote Indication location on tank taps as used in liquid level sensing & control.

 

Technical Specifications:-

Input:

4 - 20 mA Loop Current Input from any 2 / 3 WireProcess Transmitter

Range

-1999 To 1999 with Range Lock / Unlock; programmableby user

Resolution

0.001, 0.01, 0.1, 1; programmable by user

Accuracy

Linear - +/-0.1 percent of span; Square root - +/-0.2percent of span

Operational Mode

Linear & Square root; programmable byuser

Loop Voltage Drop

< 5 VDC

Display

0.5 inch, 3 1/2 digit L.C.D Display

Display Update Rate

Linear mode - 0.8 sec; Square root mode- 0.8 sec

Monitor:

Display shows Und, when I/P current fallsbelow 3.6 mA

Display shows our, when I/P current goes above 20.5 mA

Operating Temperature

- 40 To 85 Deg.C

Relative Humidity

Below 95percent non condensing

Warm up Time

10 Sec

Enclosure Detail

PANEL MOUNTING ENCLOSURE

Protection Class

IP - 40

Cabinet Material

ABS PLASTIC, White Colour

Cable Entry

Terminal Connector For Connection

Dimension

96 (H) X 96 (W) X 75 (D) in mm

Cutout

92 (H) X 92 (W) in mm

Mounting

Panel Mounting

Weight

Approx. 250 Grams