Loop Power Indicator Panel Mount

Loop Power Indicator Panel Mount
Loop Power Indicator Panel Mount
Price And Quantity
  • 1
  • Piece/Pieces
    Product Specifications
    • +/- 1 percent Of Full Scale Value. %
    • ABS PLASTIC, White Color
    • 4 - 20 mA Loop Current Input from any 2 / 3 Wire Process Transmitter Milliampere (mA)
    • 96 (H) X 96 (W) X 75 (D) in mm
    • Approx. 250 Grams (g)
    Product Description

    FEATURES:-

    • Minimum loop voltage drop
    • Option of range locking and unlocking
    • High level of accuracy
    • User Programmable with Password Protection.
    • Easy Programming with Push Buttons.
    • Software Calibration - No Trim pots.
    • Reverse Polarity Protection.
    • Loop Voltage Drop < 5 VDC.
    • 4-20 mA Loop Current Input from Transmitters.
    • Accuracy +/- 1 percent Of Full Scale Value.
    • 0.5 inch, 3 1/2 Digit L.C.D Display.
    • Range Locking / Unlocking Facility.
    • Offset Facility To Compensate Field Error.
    • Operational Mode Linear / Square Root; Programmable by user.


    APPLICATIONS:-

    • Provides Process value Indicator in various Industrial Control & Measurement Application such as Pressure, Flow, Level, Temp.,Humidity etc.
    • Remote Indicator at point of measurement or at control end especially where there is no power source.
    • Being Non Voltage Producing Device can be directly used in Hazardous Area with Suitable Enclosure.
    • Replaces an Analog Meter with no additional wiring and power connection.
    • Can be inserted at any point in signal loop as a standaloneas it requires no external power.
    • Remote Indication location on tank taps as used in liquid level sensing & control.

     

    Technical Specifications:-

    Input:

    4 - 20 mA Loop Current Input from any 2 / 3 WireProcess Transmitter

    Range

    -1999 To 1999 with Range Lock / Unlock; programmableby user

    Resolution

    0.001, 0.01, 0.1, 1; programmable by user

    Accuracy

    Linear - +/-0.1 percent of span; Square root - +/-0.2percent of span

    Operational Mode

    Linear & Square root; programmable byuser

    Loop Voltage Drop

    < 5 VDC

    Display

    0.5 inch, 3 1/2 digit L.C.D Display

    Display Update Rate

    Linear mode - 0.8 sec; Square root mode- 0.8 sec

    Monitor:

    Display shows Und, when I/P current fallsbelow 3.6 mA

    Display shows our, when I/P current goes above 20.5 mA

    Operating Temperature

    - 40 To 85 Deg.C

    Relative Humidity

    Below 95percent non condensing

    Warm up Time

    10 Sec

    Enclosure Detail

    PANEL MOUNTING ENCLOSURE

    Protection Class

    IP - 40

    Cabinet Material

    ABS PLASTIC, White Colour

    Cable Entry

    Terminal Connector For Connection

    Dimension

    96 (H) X 96 (W) X 75 (D) in mm

    Cutout

    92 (H) X 92 (W) in mm

    Mounting

    Panel Mounting

    Weight

    Approx. 250 Grams