Cookie Img

Oxygen Meter

Oxygen Meter
Oxygen Meter
Product Code : GA-3511-WP
Price And Quantity
Minimum Order Quantity :
1
Unit of Measure :
Piece/Pieces
Product Specifications
Accuracy :
±2% of Full Scale mm
Material :
Poly-carbonate, Grey Colour
Voltage :
240VAC / 50 Hz (±10%) Biot ( Bi)
Size :
330 mm(H) x 325 mm(W) x 170 mm(D) (With Gland)
Weight :
Approx 1.2 Kilograms (kg)
Product Description

Oxygen Meter

An oxygen sensor is a device used to measure the proportion of oxygen in any gas or liquid. It is widely used in engines in automobiles to evaluate the exhaust gas concentration of oxygen gas for the purpose of combustion. In addition, it is also used in other vehicles to calculate and dynamically adjust the fuel as well as air ratio to make the catalytic converters work optimally. Moreover, divers also use this device to determine the pressure of oxygen in breathing gas. It is an affordable, accurate and durable tool for spot-checking the oxygen levels. This is a portable device can be easily carried from one place to another. In addition, its heavy duty design ensures it rough and tough applications in any environment. 

 

Features :

  •  Provides a fast and reliable output by using Electro Chemical / Pellister Sensor Technology.
  •  Optimized for detection of smallest leak of Oxygen, Toxic and Combustible Gases.
  •  Highly resistant to poisoning and etching.
  •  Capable of detecting down to PPM, %LEL & %V/V.
  •  Digital display of Gas Concentration on LCD Display for GA-3511
  •  Standard 4-20mA signal output with configurable range.
  •  Easy handling and programming with 3 keys for Weatherproof Models.
  •  Can be programmed using Remote Control from 10 meters in line of site distance.
  •  Non - Intrusive programming for Flameproof model using Magnetic pen.
  •  Password protected programming with password changing facility.
  •  One man Auto Software Gas Calibration.
  •  Optional Alarm relay contacts with two configurable Alarm levels & one Relay for fail safe relay.
  •  Optional STEL and TWA set points can be configured for Toxic Gases.
  •  Optional RS-485 communication port with MODBUS RTU Protocol.

 

Applications :

  • Refineries
  • Cold Storage
  • Sewage Plants
  • Fertilizers Plants
  • Stack Monitoring
  • Chlorination Plant
  • Gas Metering skid
  • Gas Cylinder Bank
  • Ambient Monitoring
  • Pulp & Paper Plants
  • Oil & Gas Industries
  • Gas Pipeline Project
  • Gas Metering Station
  • Heat Treatment Plants
  • Chemical Storage Area
  • Control Atmosphere
  • Burner / Furnace Areas
  • Power & Industrial Plants
  • Bullet Yard / Storage Yard
  • Chemical Processing Plant
  • Coal Mine and Confined Area
  • Chemical & Petrochemical Plants
  • Acid Alkalizes & Dyes Mfg. Plants
  • Automotive Industries / Paint Shops
  • Offshore Drilling & Processing Platforms

 

Technical Specifications :

General :

Detection Method

Suction method by using vacuum pump

Gases Detected

Oxygen / Toxic / Combustible Gases (please define)

Display

8x2 Alphanumeric LCD Display with Backlit & 8 LEDs to indicate status of instrument

Control Action

Two independent alarm set points with Latch & Non-Latch Facility.

User selectable Hysteresis and Logic option.

Configurable STEL and TWA set points for Toxic Gases (Optional)

Setting

By 3 Keys on front panel.

Performance :

Accuracy

±2% of Full Scale.

Response Time

Less than 10 seconds.


Supply Voltage

240VAC / 50 Hz (±10%)

Power Consumption

Less than 20 Watts.

Cable

For Weatherproof Model : 3 Wire (1.5 mm2) Flexible Cable.

For Flameproof Model : 3 Core copper wire, Shielded Armored Cable.


 

Weatherproof Housing :

Protection Class

IP-65

Cabinet Material

Polycarbonate, Grey Colour

Cable Entry

Thermoplastic Cable Gland (IP 68)

Dimension

330 mm(H) x 325 mm(W) x 170 mm(D) (With Gland)

Mounting

Wall Mounting / Stand Mounting / Pipe Mounting

Weight

Approx 1.2 kg

Output Signal :

Standard

4-20mA Current Output with configurable range selection with 470 ohm load driving capacity.

Optional

Three SPDT Relay (one for FailSafe and Two for Alarm indication) of rating. 5A/250VAC, 5A/ 30VDC

0 to 10 VDC

Optional

RS-485 isolated Port with MODBUS RTU protocol.

 

Error Monitoring :

  •  During Sensor Break / Open, the Display shows SENSOR OPEN & 4-20mA output goes down to 3.7mA. for Combustible gases only.
  •  During Over Range, the Display shows OVER RANGE & 4-20mA output goes up to 21 mA.

Environmental :

Operating Temperature

0° to +50°C

Storage Temperature

-10° to + 60°C

Humidity

Less than 95% Non-Condensing.


Accessories (Optional) :

  • Certified 24 VDC Power Supply.
  • Canopy & Stand Mounting.
    • Gas Calibration Kit (0.5,1,3,10) Liter.
  • Hooter Cum Flasher.
  • Gas Sampling & Conditioning System.
  • RS-485 to USB OR RS-232 Converter.
  • PC Based SCADA Software, Modem.


Oxygen Meter

An oxygen sensor is a device used to measure the proportion of oxygen in any gas or liquid. It is widely used in engines in automobiles to evaluate the exhaust gas concentration of oxygen gas for the purpose of combustion. In addition, it is also used in other vehicles to calculate and dynamically adjust the fuel as well as air ratio to make the catalytic converters work optimally. Moreover, divers also use this device to determine the pressure of oxygen in breathing gas. It is an affordable, accurate and durable tool for spot-checking the oxygen levels. This is a portable device can be easily carried from one place to another. In addition, its heavy duty design ensures it rough and tough applications in any environment. 

 

Features :

  •  Provides a fast and reliable output by using Electro Chemical / Pellister Sensor Technology.
  •  Optimized for detection of smallest leak of Oxygen, Toxic and Combustible Gases.
  •  Highly resistant to poisoning and etching.
  •  Capable of detecting down to PPM, %LEL & %V/V.
  •  Digital display of Gas Concentration on LCD Display for GA-3511
  •  Standard 4-20mA signal output with configurable range.
  •  Easy handling and programming with 3 keys for Weatherproof Models.
  •  Can be programmed using Remote Control from 10 meters in line of site distance.
  •  Non - Intrusive programming for Flameproof model using Magnetic pen.
  •  Password protected programming with password changing facility.
  •  One man Auto Software Gas Calibration.
  •  Optional Alarm relay contacts with two configurable Alarm levels & one Relay for fail safe relay.
  •  Optional STEL and TWA set points can be configured for Toxic Gases.
  •  Optional RS-485 communication port with MODBUS RTU Protocol.

 

Applications :

  • Refineries
  • Cold Storage
  • Sewage Plants
  • Fertilizers Plants
  • Stack Monitoring
  • Chlorination Plant
  • Gas Metering skid
  • Gas Cylinder Bank
  • Ambient Monitoring
  • Pulp & Paper Plants
  • Oil & Gas Industries
  • Gas Pipeline Project
  • Gas Metering Station
  • Heat Treatment Plants
  • Chemical Storage Area
  • Control Atmosphere
  • Burner / Furnace Areas
  • Power & Industrial Plants
  • Bullet Yard / Storage Yard
  • Chemical Processing Plant
  • Coal Mine and Confined Area
  • Chemical & Petrochemical Plants
  • Acid Alkalizes & Dyes Mfg. Plants
  • Automotive Industries / Paint Shops
  • Offshore Drilling & Processing Platforms

 

Technical Specifications :

General :

Detection Method

Suction method by using vacuum pump

Gases Detected

Oxygen / Toxic / Combustible Gases (please define)

Display

8x2 Alphanumeric LCD Display with Backlit & 8 LEDs to indicate status of instrument

Control Action

Two independent alarm set points with Latch & Non-Latch Facility.

User selectable Hysteresis and Logic option.

Configurable STEL and TWA set points for Toxic Gases (Optional)

Setting

By 3 Keys on front panel.

Performance :

Accuracy

±2% of Full Scale.

Response Time

Less than 10 seconds.


Supply Voltage

240VAC / 50 Hz (±10%)

Power Consumption

Less than 20 Watts.

Cable

For Weatherproof Model : 3 Wire (1.5 mm2) Flexible Cable.

For Flameproof Model : 3 Core copper wire, Shielded Armored Cable.


 

Weatherproof Housing :

Protection Class

IP-65

Cabinet Material

Polycarbonate, Grey Colour

Cable Entry

Thermoplastic Cable Gland (IP 68)

Dimension

330 mm(H) x 325 mm(W) x 170 mm(D) (With Gland)

Mounting

Wall Mounting / Stand Mounting / Pipe Mounting

Weight

Approx 1.2 kg

Output Signal :

Standard

4-20mA Current Output with configurable range selection with 470 ohm load driving capacity.

Optional

Three SPDT Relay (one for FailSafe and Two for Alarm indication) of rating. 5A/250VAC, 5A/ 30VDC

0 to 10 VDC

Optional

RS-485 isolated Port with MODBUS RTU protocol.

 

Error Monitoring :

  •  During Sensor Break / Open, the Display shows SENSOR OPEN & 4-20mA output goes down to 3.7mA. for Combustible gases only.
  •  During Over Range, the Display shows OVER RANGE & 4-20mA output goes up to 21 mA.

Environmental :

Operating Temperature

0° to +50°C

Storage Temperature

-10° to + 60°C

Humidity

Less than 95% Non-Condensing.


Accessories (Optional) :

  • Certified 24 VDC Power Supply.
  • Canopy & Stand Mounting.
    • Gas Calibration Kit (0.5,1,3,10) Liter.
  • Hooter Cum Flasher.
  • Gas Sampling & Conditioning System.
  • RS-485 to USB OR RS-232 Converter.
  • PC Based SCADA Software, Modem.


Contact Us

17-B, Tarun Industrial Estate, Mogra Pada, New Nagardas Road, Andheri (East), Mumbai, Maharashtra, 400069, India
Phone :+917259672294