AMBETRONICS ENGINEERS PVT. LTD.
Panel Tachometer

Panel Tachometer

Send Inquiry

Our aim is to provide quality assured products to our valuable clients by manufacturing and supplying Panel Tachometer. These instruments are used in control rooms, alarm shutdowns, field testing and data acquisition purposes. Our highly diligent workforce uses finest quality materials and components, sourced from the authentic vendors to manufacture the tachometer. The Panel Tachometer uses one sensor - rotational and loop or reciprocating motion systems. We offer our instruments at the pocket friendly prices.

Features:

  • Programmable panel
  • High accuracy
  • Longer service life

Features:

ACT-1B (5-99,999 RPM)

  • One pulse/revolution (ACT-1B) or 60 pulses/revolution (ACT-1B-60)
  • Output options: 4-20 mA (12 bit), 0-5 Vdc (12 bit) or TTLpulse

ACT-2A (5-999,990 RPM)

  • Front panel programmable
  • One or multiple pulses/revolution, scaling or totalizing
  • Minimum and maximum memory recall

ACT-3 (5-999,990 RPM)

  • N.I.S.T. Traceable Certificate of Calibration included
  • Simultaneous 4-20 mA, 0-5 Vdc (12 bit), TTLpulse and 2Alarm outputs and RS232.
  • Single event speed capture from start and stop pulses, in units such as MPH, cm/sec, etc. Using one sensor - rotational, loop or reciprocating motion. Using two sensors - linear travel.

Applications :

  • Control rooms
  • Alarm shutdowns
  • Field testing
  • Data acquisition
  • R&D testing

Technical Data

Type

ACT-1B

ACT-3X

Speed Range

5 to 99,999 RPM

5 to 999,990 RPM (single pulse per revolution),+0.5 to 999,990 RPM (10 pulses per revolution). Speeds below 5 RPM are possible with multiple pulses per revolution

Accuracy

+1 RPM or 0.005% of reading

+0.001% of reading or+1 displayed resolution (Standard Gate), +0.01% of reading or +1 displayed resolution (Fast Gate).

Resolution

1 RPM

Up to 0.001 RPM, 10 RPM (100,000 to 999,990 RPM)

Display

5 digit, 0.56 (14 mm) high red LED

5 digit, 0.56 (14 mm) high red LED

Display Update

Twice per second above 120 RPM. Programmable with PM Remote Software and USB programming cable.

Menu Selectable between: 0.5 second above 120 RPM, 1 second above 60 RPM and 1.5 seconds above 40 RPM.

Dimensions

1/8 DIN by 4.5 (114 mm) deep. Panel cutout: 3.58 x 1.74 (91 x 44mm)

1/8 DIN by 4.5 (114 mm) deep. Panel cutout: 3.58 x 1.74 (91 x 44mm)

Input Power

Standard: 100 - 240 Vac +10%, 50/60 Hz  Optional:+12 or 24 Vdc +10%, Isolated, 6.0 Watts

Standard: 100 - 240 Vac +10%, 50/60 Hz  Optional:+12 or 24 Vdc +20%, Isolated, 6.0 Watts

Inputs

Universal input for optical, proximity, two wire or three wire magnetic, infrared or laser sensors. TTL input or 1.5 Vac to 50 Vac input. Standard input is 1 pulse per revolution.

Universal input for optical, proximity, two wire or three wire magnetic, infrared or laser sensors. TTL input or 1.5 Vac to 50 Vac input. Standard input is 1 pulse per revolution.

Sensor Excitation

5Vdc or optional 12Vdc or 24Vdc to senso

5Vdc or optional 12Vdc or 24Vdc to sensor

Recommended Sensors

Optical - Monarch ROS-W, ROS-P-25, ROS-HT-W-25, ROSM-5W

Proximity - Monarch P5-11

Magnetic - Monarch M-190W or MT-190W

Infrared - Monarch IRS-W

Laser - Monarch ROLS-W, SLS-115/230

Inductive - Gas Engine GE-200

Optical - Monarch ROS-W, ROS-P-25, ROS-HT-W-25, ROSM-5W

Proximity - Monarch P5-11

Magnetic - Monarch M-190W or MT-190W

Infrared - Monarch IRS-W

Laser - Monarch ROLS-W, SLS-115/230

Inductive - Gas Engine GE-200

Analog Output

(Optional)

VOLTAGE (AO): 0 to 5 Vdc out, 5 mA 16 bit resolution. Full scale RPM settings as specified when ordered or programmable using PM Remote Software and USB programming cable. or CURRENT (IO): 4 to 20 mA out, 16 bit resolution 12Vdc compliance voltage. Full scale RPM settings as specified when ordered or programmable using PM Remote Software and USB programming cable.

Voltage (AO): 0 to 5 Vdc, 5mA max load (isoloated or non-isolated) or Current (IO): 4 to 20mA, 500 max load. (isolated or non-isolated), 1 to 5Vdc possible using 250 resistor) 16 bit resolution. Front panel push button programmable for full scale and offset RPM ranges.

Pulse Output

0 to 5 V TTL pulse, non-inverting, one pulse out for each pulse in. Positive or negative out. Programmable using PM

Remote Software and USB programming cable.

Standard, 0 to 5 V TTL compatible. One pulse out for each pulse in. Menu selectable polarity

Remote Programming

Unit can be remotely programmed using optional communications interface cable and PM Remote Software.

Unit can be remotely programmed using optional communications interface and PM Remote Software.

Environmental

Indoor use only, Installation category II per IEC 664 Temperature: -10oC to 50oC operating per IEC 61010-1 Humidity: Maximum relative humidity 80% for temperatures up to 31oC, decreasing linearly to 50% relative humidity at 40C

Indoor use only, Installation category II per IEC 664 Temperature: -10oC to 50oC operating per IEC 61010-1 Humidity: Maximum relative humidity 80% for temperatures up to 31oC, decreasing linearly to 50% relative humidity at 40C

Electrical Safety

Meets EN61010-1:2001, EC low voltage directive 72/23/EEC and 89/336/EEC

Meets EN61010-1:2001, EC low voltage directive 72/23/EEC and 89/336/EEC