AMBETRONICS ENGINEERS PVT. LTD.
PROGRAMMABLE AMPERE HOUR CONTROLLER

PROGRAMMABLE AMPERE HOUR CONTROLLER

Send Inquiry

 

AHC 100 Programmable Ampere Hour Controller

FEATURES: 

  • Based on state of art latest micro controller technology with Watchdog feature for fail safe operation.
  • Acceptability of analog input from DC Shunt.
  • A high resolution of 20000 counts (max) for Ampere rate & 999999 counts (max) for Ampere Hour Totalizer & Batch counter.
  • Highly informative, user friendly display & keyboard interface with indication for Ampere rate, Total & Batch.
  • Relay control action can be programmable.
  • Programmable latch OR non-latch facility for relay & relay indication.
  • User selectable batch quantity, batch counter & reset facility through keyboard & external contacts.
  • Non-Volatile battery backup memory to store data in case of power failure with configurable power up recovery option.
  • Isolated RS485 communication with MODBUS RTU Protocol.
  • Isolated retransmission of process value signal (Optional).
  • Configurable retransmission range setting by users.
  • Flameproof version is available on request.  

APPLICATIONS: 

  • Metal Extrusion
  • Electroplating
  • Electro Polishing & Galvanizing
  • P.C.B. Manufacturing
  • Battery Charging
  • Hydro Generations
  • Electro Dip Painting
  • D.C. Substation  

TECHNICAL SPECIFICATION

Analog Input from 

 0 - 75mV from DC Shunt.

Sensor Break

 Under Range 'UndEr' Over range 'ouEr' indication for 0-75mV. 

Range

 0 to 20000 (5 digit) counts of Ampere rate configurable as per Second, Min, Hour.
 0 to 999999 (6 digit) counts of Ampere Hour Totalizer.
 0 to 999999 (6 digit) Batch counter to know total no. of Batch completed.

Resolution

 Field programmable decimal point selection for Ampere Indication by users.

Accuracy

 Better than 0.1% of full scale reading..

Setting

 By 3 keys on front panel i.e. Keys.

Alarm Output

 2 Independent set points for Ampere Hour Totalizer setting. 
 2 independent NO/C/NC contact for Ampere Hour Totalizer setting. 

Relay Specification

 5Amp. / 250VAC, 5Amp. / 30VDC at resistive load. 

Control Action

 L & H, H & VH, L & VL control action facility individual for each relay. 
 Auto reset pulse output for Batch application.

Display

 5 Digit for Ampere rate OR 6 Digit for Totalizer, selectable by using (+) key on Front panel.
 8 L.E.D.'s for RL1, RL2, TX, RX, PROG., SQR, RATE & TOTAL.

Memory

 Non-Volatile memory to store the Totalizer value, Batch count in case of 
 power failure with 4 options of power up recovery i.e. No memory recovery, 
 Batch memory recovery, Totalizer memory recovery & All memory recovery.

Reset

 Provision for Total reset from the panel as well as remote reset from back 
 Terminal through potential free contacts input for Ampere Hour Totalizer.

Supply

230VAC +10% OR 110VAC +10% OR 24VDC.

Mounting

 Panel mounting / Wall mounting for flameproof model.

Dimension

 96(W) X 48(H) X 120(D) in mm. OR 72(W) X 72(H) X 120(D) in mm ( Including back side connecter )

Cutout

 92(W) X 44(H) in mm. OR 68(W) X 68(H) in mm.

Cabinet

 ABS Plastic, Black Color for [96(W)X48(H)X120(D)] & White Color for [72(W)X72(H)X120(D)]

Optional

 a) Isolated RS485 Serial port with MODBUS RTU Protocol output for PC interface.
 b) Isolated 4 to 20mA retransmission programmable output for recorder or PLC proportional to selective range.
 c) Flameproof version is available on request for hazardous application. 

Important

 MODBUS RTU Protocol support to update instrument setting through PC. Powerful SCADA software is available.

Weight

 1 Kg.