    Rack Type Multichannel  Monitor

    FEATURES: 

    • Fail Safe Operation Design.
    • Continues Gas Monitoring and Alarm System.
    • Modular Design Card with Individual Display with Bar Graph indication for each sensor.
    • Easily Expandable & easy for maintenance.
    • Individual Alarm Relay/Open collector outputs for each sensor.
    • Range, Resolution, Control Action, Latch Facility Programmable by Users/ Multilayer Password Protected.
    • Inhibit/service mode, at the time of maintenance Alarm Relay become inactive.
    • Easy Automatic software calibration - No Trim Pots.
    • Optional Programmable linear 4~20 mA output with respect to Gas Concentration. 

     

    APPLICATIONS: 

    • Oil & Gas Industries
    • Chemical & Petrochemical Plants
    • Chemical Processing Plant
    • Pulp & Paper Plants
    • Acid Alkalizes & Dyes Mfg. Plants.
    • Offshore Drilling & Processing
    • Platforms
    • Refineries
    • Stack Monitoring
    • Chemical Storage Area
    • Ambient Monitoring
    • Sewage Plants
    • Fertilizers Plants
    • Power & Industrial Plants
    • Gas Metering Station
    • Bullet Yard / Storage Yard
    • Coal Mine and Confined Area
    • Gas Pipeline Project
    • Gas Cylinder Bank
    • Heat Treatment Plants
    • Automotive Industries / Paint Shops
    • Burner / Furnace Areas 




    TECHNICAL SPECIFICATIONS:

    Input

    4 to 20mA output from Oxygen / Toxic / Combustible 2/3 Wire Gas Transmitters

    Range

    -99 to 999 programmable by user, reads % L.E.L.,%L.F.L., P.P.M. OR % VOL.

    Resolution

    0.01, 0.1, 1 programmable by user

    Accuracy

    + 0.5 % of the full scale value

    No. of Input cards

    Max. 16 module cards (Optional available 24 nos. and 48 nos. depends upon panel size )

    Display

    1)3 Digits of 8mm (Height) Red L.E.D display for Gas Concentration

    2) 20 segment Red color Bar Graph Display for Gas Concentration 100% Full scale, 5% Per step L.E.D

    LED Indication

    8 No, AL1, AL2, AL3, Health Check / Failsafe Indication, PRG, CAL, Optional TX for Transmitting signal & RX for Receiving signal.

    Set point

    3 Independent Alarm set point programmable by user AL1, AL2, AL3

    Control action

    LO / HI, HI / LO, LO/ Very LO, HI-Very HI, Programmable by user AL1, AL2, AL3

    Hysteresis

    0 to 10 counts, Individual setting for AL1,AL2 & AL3 programmable by user

    Relay Output

    4 NO, 1 NO/C/NC relay contact rated 230VAC / 5A for AL1, AL2, AL3 and Failsafe Relay

    Relay Latching

    Programmable Latch / Non-Latch facility for AL1, AL2 & AL3

    Setting

    Setting by 4 keys on front panelSet/NextUpDownTest /

    Monitoring

    i) By Display : Sensor Break / Open shows Under range shows Und & Over range shows

    ii) By Current O/P : Upscale current >21mA, Down scale current < 1mA, selectable

    Supply Voltage

    18 to 36 VDC, 24 VDC normal for module card OR 230V AC+ 10% for wall mounted panel

    Cable

    1.5 sq. mm 3 Core OR 2 Core, Flexible OR Armored shielded cable from Gas transmitter to Monitor

    Operating Temperature

    0 to 50oC + 5%, Relative Humidity: Below 95% non Condensing

    Cabinet Material

    Aluminum housing with powder coating

    Terminal

    20 connectors with 1.5 Sq. mm. Wire connection facility for each channel on back side of panel

    Mounting

    Panel mounting / Wall mounting

    DETAILS

    No. Of Channels

    Dimension in mm (Approx)

    Cutout Size in mm (Approx)

    Weight in Kg



    ( W )

    (H)

    (D)

    (W)

    (H)

    (Approx)


    2 Channel Rack

    118

    134

    200

    63

    134

    1.0


    4 Channel Rack

    157

    134

    200

    113

    134

    2.5


    8 Channel Rack

    260

    134

    200

    215

    134

    4.0


    16 Channel Rack

    484

    134

    200

    439

    134

    7.5


    Complete Gas Detection Panel

    575

    357

    425

    -----

    -----

    15.0

    Optional

    a)Isolated RS-485 Serial port with MODBUS RTU Protocol output for PC interface

    b) Isolated 4-20mA retransmission output for PLC, DCS, any recorder

    c) 4 NO, Open Collector O/P rated 100mA at 32VDC instead of 4 NO Relay

    d) SMARTLOG / SCADA SOFTWARE for online graph & data report for safety Audit or real time graph, history data, alarm report

    e) Flame Proof or Non Flame Proof Industrial Hooter, Hooter cum Flasher, Chart recorder, Cables, PC Software, Gas Transmitters, 24 VDC power supply, Gas calibration kit.

    Trade Information
    • Mumbai
    • 3 to 4 weeks Week
    • All India
    Contact Us

    17-B, Tarun Industrial Estate, Mogra Pada, New Nagardas Road, Andheri (East), Mumbai, Maharashtra, 400069, India
    Phone :+918068090472